Limited Time 30% Discount Offer Use Code - off30

1Z0-1091-22 - Bundle Pack

Actualkey Prepration Latest 1Z0-1091-22 : Oracle Utilities Meter Solution Cloud Service 2022 Implementation Professional Exam Questions and Answers PDF's, Verified Answers via Experts - Pass Your Exam For Sure and instant Downloads - "Money Back Guarantee".


Vendor Oracle
Certification Oracle Cloud Solutions
Exam Code 1Z0-1091-22
Title Oracle Utilities Meter Solution Cloud Service 2022 Implementation Professional Exam
No Of Questions 51
Last Updated July 1,2024
Product Type Q & A with Explanation
Bundel Pack Included PDF + Offline / Andriod Testing Engine and Simulator

Bundle Pack

PRICE: $25

1Z0-1091-22 : BUNDLE PACK LEARNING TOOLS INCLUDED

Actualkey Products

PDF Questions & Answers

Exam Code : 1Z0-1091-22 - Jul 1,2024
Try Demo
Testing Engine

Offline Test Engine

Exam Code : 1Z0-1091-22 - Jul 1,2024
Try Demo
android testing engine

Android Test Engine

Exam Code : 1Z0-1091-22 - Jul 1,2024
Try Demo
online Exam Engine

Online Test Engine

Exam Code : 1Z0-1091-22 - Jul 1,2024
Try Demo

Earn associated certifications
Passing this exam is required to earn these certifications. Select each certification title below to view full requirements.

Oracle Utilities Meter Solution Cloud Service 2022 Certified Implementation Professional
Format: Multiple Choice
Duration: 90 Minutes
Number of Questions: 55
Passing Score: 70%
Validation: This exam has been validated against Oracle Utilities Customer Cloud Service 22A and 22B
Policy: Cloud Recertification

Prepare to pass exam: 1Z0-1091-22
An Oracle Utilities Meter Solution Cloud Service 2022 Implementation Professional has demonstrated the knowledge required to implement and configure the service; including Service Points, Devices, Measuring Components, Usage Subscriptions, and Usage Calculation Rules. They can set up Dynamic Aggregations, integrate with customer information systems (CIS), and configure the Smart Grid Gateway (SGG) SaaS Architecture.

Review exam topics

Service Points, Devices and Measuring Components
Explain key concepts Service Points, Devices and Measuring Components
Configure Service Points, Devices and Measuring Components and Measurement Cycles

Measurements
Describe and implement intial measurements, final measurements, and derrived values
Describe Measurement Reprocessing functionality and Substractive Interval Data
Implement Best practices for measurement retention

Map Interval Measurements To Time-of-Use Periods
Explain the key concepts of Time-of-Use (TOU) and how it applies to final measurements
Configure work calendars
Generate TOU map data and check for correctness

VEE: Validation, Estimation and Editing
Explain VEE rules and exceptions
Configure VEE rules and exceptions, including the VEE rules used by the consumption synchronization process
Configure Advanced Estimations

Usage Subscriptions
Explain usage subscriptions
Design and set up the admin data required to effectively configure a usage subscription

Usage Calculation Groups / Rules and Usage Transactions
Explain Usage Calculation Groups / Rules and Usage Transactions
Configure base package usage calculation rules
Configure dynamic rate determination
Configure eligibility criteria for Usage Rules
Configure the Usage Rule - Math usage rule to perform mathematical operations on service quantities
Configure a Dynamic Option Type

Dynamic Aggregations
Explain the main components of Dynamic Aggregations
Set up and understand Dynamic Aggregations

Integrations
Describe DataConnect
Integrate with Customer Information Systems

Smart Grid Gateway (SGG) SaaS Overview, Adapters and Integrations
Describe Smart Grid Gateway (SGG) SaaS
Configure the Smart Grid Gateway (SGG) SaaS Architecture

Smart Grid Gateway (SGG) SaaS Payload Processing
Describe Usage and Event Upload
Explain the cloud service payload processing configuration

Device Events
Configure Standard Event Names
Configure Device Events to support filtering of momentary outage events

Smart Grid Gateway (SGG) SaaS Command Processing
Configure Head-End Systems
Describe the commands generally supported by SGG adapters and the Adapter Development Kit (ADK)
Set up and configure commands

Service Order Management
Describe Service Order Management and Service Investigative Orders
Configure Service Order Activities
Configure Service Investigative Orders

Operational Device Management
Explain the role of assets and components
Configure specifications and their relationship to assets

QUESTION 1
A business needs a new Service Order process that includes meter commands. Which THREE options should you configure to build this process?

A. Measuring component type
B. Device configuration type
C. Activity type
D. Communication type Message sender

Answer: ACD

To build a new Service Order process that includes meter commands, you need to configure the following options:
Measuring component type: This defines the type of measurement that a device can record, such as
scalar, interval, or event. You can associate meter commands with measuring component types to
perform actions on devices that have those types1.
Activity type: This defines the type of work that needs to be performed on a service point or device,
such as installation, removal, or inspection. You can associate meter commands with activity types to
trigger actions on devices when an activity is completed1.
Communication type Message sender: This defines the communication channel and protocol that is
used to send meter commands to devices. You can configure message senders for different
communication types, such as AMI, AMR, or manual1.
You do not need to configure device configuration type, which defines the physical characteristics
and attributes of a device, such as manufacturer, model, or serial number1. Device configuration
type does not affect meter commands.
Reference: 1: Oracle Utilities Meter Solution Cloud Service - Business User Guide - Chapter 4:
Configuring Meter Solution Cloud Service

QUESTION 2
In the SaaS solution, how should you configure equipment that attaches to an asset, such as a communication module attached to a meter?

A. Set up a component
B. Create a master child asset
C. Add a sub-asset
D. Add a constituent part

Answer: A

To configure equipment that attaches to an asset, such as a communication module attached to a
meter, you should set up a component. A component is a part of an asset that can be installed and
removed independently of the asset. You can define component types and associate them with asset
types. For example, you can define a communication module component type and associate it with a meter asset type2.
You do not need to create a master child asset, which is a relationship between two assets that are
installed at different service points but are functionally related. For example, you can define a
transformer as a master asset and a meter as a child asset2. A master child asset is not suitable for
equipment that attaches to an asset.
You do not need to add a sub-asset, which is an asset that is installed at the same service point as
another asset but has its own measuring components and usage subscriptions. For example, you can
define a meter as a sub-asset of another meter if they share the same service point but have
different measurements2. A sub-asset is not suitable for equipment that attaches to an asset.
You do not need to add a constituent part, which is an attribute of an asset that cannot be installed
or removed independently of the asset. For example, you can define a battery as a constituent part
of a meter if it is embedded in the meter and cannot be replaced2. A constituent part is not suitable
for equipment that attaches to an asset.
Reference: 2: Oracle Utilities Meter Solution Cloud Service - Business User Guide - Chapter 5: Managing Assets

QUESTION 3
3. For a Meter Data Management (MDM) implementation, customer information system (CIS) requires the following bill determinants:
For scalar meters, scalar consumption values will be sent to CIS.
For interval meters, billed on time-of-use (TOU) rates, consumption values will be provided based
on the specific TOU periods, for example: on-peak, off-peak, and shoulder.
Based on these requirements, which TWO usage subscription or usage calculation group
configuration options should you set up to allow an implementation to send bill determinants to CIS?

A. Scalar specific group as a fallback Validation, Estimation, and Editing (VEE) group.
B. TOU usage group as a fallback VEE group.
C. Scalar usage calculation rule with a valid usage group.
D. TOU usage rule with a valid usage group.

Answer: C

To allow an implementation to send bill determinants to CIS based on the requirements, you should
set up the following usage subscription or usage calculation group configuration options:
Scalar usage calculation rule with a valid usage group: This defines how scalar consumption values
are calculated from measurements and sent to CIS. You can define scalar usage calculation rules for
different measurement types and associate them with usage groups. A usage group is a collection of
usage calculation rules that are applied to measurements based on certain criteria3.
TOU usage rule with a valid usage group: This defines how TOU consumption values are calculated

SATISFIED CUSTOMERS